Oracle ZFS Hardware Status Test

This test monitors the overall status of the hardware and serves as an effective health indicator for the following system components:

  • Disk

  • Fan

  • Memory

  • Power Supply Unit

This test alerts the administrator in case of faults in any of the hardware components.

Target of the test : Oracle ZFS Storage System

Agent deploying the test : A remote agent

Outputs of the test : One set of results for each controller:hardware type:hardware component in the Oracle ZFS Storage System being monitored.

Configurable parameters for the test
Parameter Description

Test period

How often should the test be executed.

Host

The IP address of the target system that is being monitored.

Port

The port number through which Oracle ZFS Storage System communicates. The default port is 215.

User, Password and Confirm Password

By default, this test uses the REST API commands to pull out the required metrics. To execute the REST API commands, the eG agent requires the permission of a local administrator user who has been assigned with Basic role and a custom role with Analytics authorization and read permission. Specify the credentials of such a user in the USERNAME and PASSWORD text boxes and confirm the Password by retyping it in the CONFIRM PASSWORD text box. To create a new user with the required permissions, refer Creating a new user on Oracle ZFS Storage System.

Timeout

Specify the time duration for which this test should wait for a response from the storage system in the TIMEOUT text box. By default, this is 60 seconds.

Measurements made by the test
Measurement Description Measurement Unit Interpretation

Is present?

Indicates the status of the hardware component available in the controller.

 

The values reported by this measure and its numeric equivalents are mentioned in the table below:

Measure Value

Numeric Value
No 0
Yes 100

Note:

By default, this measure reports the Measure Values listed in the table above to indicate the status of the hardware component available in the controller.

Is faulted?

Indicates whether/not the hardware component is defective.

 

The values reported by this measure and its numeric equivalents are mentioned in the table below:

Measure Value

Numeric Value
No 0
Yes 100

Note:

By default, this measure reports the Measure Values listed in the table above to indicate whether/not the hardware component is defective.