v7000 Enclosures Test
Each IBM Storwize V7000 system has one or two (optional) control enclosures that contain node canisters, disk drives, and power supply units. If a control enclosure is not visible to the SAN, then users will not be able to access the storage system. This is why, administrators need to closely monitor the state of each enclosure, and ensure its continuous availability to the SAN. This can be achieved using the v7000 Enclosures test. This test monitors each enclosure and reports its current state and composition, so that administrators can be instantly alerted to the abnormal state of the enclosure.
Target of the test : An IBM Storwize v7000 storage system
Agent deploying the test : A remote agent
Outputs of the test : One set of results for every enclosure being monitored.
Parameter | Description |
---|---|
Test Period |
How often should the test be executed. |
Host |
The host for which the test is to be configured. |
Port |
The port number at which the specified host listens to. By default, this is NULL. |
Timeout |
Specify the duration (in seconds) beyond which the test will timeout in the Timeout text box. The default value is 60 seconds. |
Detailed Diagnosis |
To make diagnosis more efficient and accurate, the eG Enterprise embeds an optional detailed diagnostic capability. With this capability, the eG agents can be configured to run detailed, more elaborate tests as and when specific problems are detected. To enable the detailed diagnosis capability of this test for a particular server, choose the On option. To disable the capability, click on the Off option. The option to selectively enable/disable the detailed diagnosis capability will be available only if the following conditions are fulfilled:
|
Measurement | Description | Measurement Unit | Interpretation | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Status |
Indicates the current status of this enclosure. |
|
This measure reports any one of the following values:
The numeric values that correspond to the above-mentioned measure values are as follows:
Note: By default, this measure reports the above-mentioned Measure Values while indicating the status of the enclosure. However, in the graph of this measure, enclosure state will be represented using the corresponding numeric equivalents only. The detailed diagnosis of this measure if enabled, lists the type of the enclosure, the managed status of the enclosure, the IO group ID, the IO group name, the machine type and the serial number of the enclosure. This way, you can accurately determine the I/O groups that will be rendered inaccessible if an enclosure goes offline or is degraded. |
||||||||||||
Total Canisters |
Indicates the total number of canisters available in this enclosure. |
Number |
|
||||||||||||
Online Canisters |
Indicates the number of canisters contained in this enclosure that are currently online. |
Number |
|
||||||||||||
Total PSUs |
Indicates the total number of power supply units available in this enclosure. |
Number |
|
||||||||||||
Online PSUs |
Indicates the number of power supply units contained in this enclosure that are currently online. |
Number |
|
||||||||||||
Drive slots |
Indicates the total number of slots that can accommodate drives in this enclosure. |
Number |
|