SDX Hardware Sensors - Power Supply Test
Citrix ADC SDX platforms can accommodate two power supplies, except the SDX 22040/22060/22080/22100/22120 and SDX 24100/24150 platforms which can accommodate four power supplies. All ADC appliances function properly with a single power supply, except the SDX 22040/22060/22080/22100/22120 and SDX 24100/24150 platforms which need two power supplies for proper operation. The other power supply(ies) serves as a backup.
Regardless of the power backup available, an administrator may want to be alerted even if a single power supply fails. This way, he/she can arrange to have that power supply replaced before the backup fails too and brings the SDX appliance down! This is where the SDX Hardware Sensors - Power Supply test helps!
This test monitors each power supply of the SDX appliance and alerts administrator if any power supply fails. This way, the test prompts administrators to quickly replace the failed supply and ensure the high availability of the SDX appliance.
Target of the test : Citrix ADC SDX
Agent deploying the test : A remote agent
Outputs of the test : One set of results for each power supply on the target ADC SDX.
Parameter | Description |
---|---|
Test Period |
How often should the test be executed. |
Host |
The host for which the test is to be configured. |
SDX Username and SDX Password |
To monitor a ADC SDX device, the eG agent should be configured with the credentials of a user with read-only privileges to the target device. Specify the credentials of such a user in the SDX Username and SDX Password text boxes. |
Confirm Password |
Confirm the password by retyping it here. |
SSL |
The eG agent collects performance metrics by invoking NITRO (ADC Interface Through Restful interfaces and Objects) APIs on the target ADC SDX device. Typically, the NITRO APIs can be invoked through the HTTP or the HTTPS mode. By default, the eG agent invokes the NITRO APIs using the HTTPS mode. This is why, the SSL flag is set to Yes by default. If the target ADC SDX device is not SSL-enabled, then the NITRO APIs can be accessed through the HTTP mode only. In this case, set the SSL flag to No. |
Measurement | Description | Measurement Unit | Interpretation | ||||||
---|---|---|---|---|---|---|---|---|---|
Status |
Indicates the current status of this power supply. |
|
The values that this measure can report and their corresponding numeric values have been listed in the table below:
Note: By default, this measure reports the above-mentioned Measure Values to indicate the current status of a power supply. However, in the graph of this measure, the Measure Values will be represented using their corresponding numeric equivalents only. |