NetApp LUN Config Errors Test
LUN conflicts may result in various issues such as data inconsistencies in the LUN as hosts may overwrite each others data or may lead to LUN reservation issues.
Conflicts may arise when a LUN is mapped to both the FCP and iSCSI initiator groups with the ALUA setting being enabled on atleast one of the initiator groups. Further mapping to the conflicted LUN will be possible only when the conflicts are resolved.
This test reports the count of LUNs that are victims of such a conflict. Using the detailed diagnosis of this test, you can identify the affected LUNs as well.
Target of the test : A NetApp Unified Storage
Agent deploying the test : An external/remote agent
Outputs of the test : One set of results for the NetApp storage system being monitored.
Parameters | Description |
---|---|
Test Period |
How often should the test be executed. |
Host |
The host for which the test is to be configured. |
Port |
Specify the port at which the specified host listens in the Port text box. By default, this is NULL. |
User |
Here, specify the name of the user who possesses the following privileges: login-http-admin,api-aggr-check-spare-low,api-aggr-list-info,api-aggr-mediascrub-list-info,api-aggr-scrub-list-info,api-cifs-status,api-clone-list-status,api-disk-list-info,api-fcp-adapter-list-info,api-fcp-adapter-stats-list-info,api-fcp-service-status,api-file-get-file-info,api-file-read-file,api-iscsi-connection-list-info,api-iscsi-initiator-list-info,api-iscsi-service-status,api-iscsi-session-list-info,api-iscsi-stats-list-info,api-lun-config-check-alua-conflicts-info,api-lun-config-check-cfmode-info,api-lun-config-check-info,api-lun-config-check-single-image-info,api-lun-list-info,api-nfs-status,api-perf-object-get-instances-iter*,api-perf-object-instance-list-info,api-quota-report-iter*,api-snapshot-list-info,api-vfiler-list-info,api-volume-list-info-iter*. If such a user does not pre-exist, then, you can create a special user for this purpose using the steps detailed in Creating a New User with the Privileges Required for Monitoring the NetApp Unified Storage. |
Password |
Specify the password that corresponds to the above-mentioned User. |
Confirm Password |
Confirm the Password by retyping it here. |
Authentication Mechanism |
In order to collect metrics from the NetApp Unified Storage system, the eG agent connects to the ONTAP management APIs over HTTP or HTTPS. By default, this connection is authenticated using the LOGIN_PASSWORD authentication mechanism. This is why, LOGIN_PASSWORD is displayed as the default authentication mechanism. |
Use SSL |
Set the Use SSL flag to Yes, if SSL (Secured Socket Layer) is to be used to connect to the NetApp Unified Storage System, and No if it is not. |
API Port |
By default, in most environments, NetApp Unified Storage system listens on port 80 (if not SSL-enabled) or on port 443 (if SSL-enabled) only. This implies that while monitoring the NetApp Unified Storage system, the eG agent, by default, connects to port 80 or 443, depending upon the SSL-enabled status of the NetApp Unified Storage system - i.e., if the NetApp Unified Storage system is not SSL-enabled (i.e., if the Use SSL flag above is set to No), then the eG agent connects to the NetApp Unified Storage system using port 80 by default, and if the NetApp Unified Storage system is SSL-enabled (i.e., if the Use SSL flag is set to Yes), then the agent-NetApp Unified Storage system communication occurs via port 443 by default. Accordingly, the API Port parameter is set to default by default. In some environments however, the default ports 80 or 443 might not apply. In such a case, against the API Port parameter, you can specify the exact port at which the NetApp Unified Storage system in your environment listens, so that the eG agent communicates with that port for collecting metrics from the NetApp Unified Storage system. |
vFilerName |
A vFiler is a virtual storage system you create using MultiStore, which enables you to partition the storage and network resources of a single storage system so that it appears as multiple storage systems on the network. If the NetApp Unified Storage system is partitioned to accommodate a set of vFilers, specify the name of the vFiler that you wish to monitor in the vFilerName text box. In some environments, the NetApp Unified Storage system may not be partitioned at all. In such a case, the NetApp Unified Storage system is monitored as a single vFiler and hence the default value of none is displayed in this text box. |
Timeout |
Specify the duration (in seconds) beyond which the test will timeout if no response is received from the device. The default is 120 seconds. |
DD Frequency |
Refers to the frequency with which detailed diagnosis measures are to be generated for this test. The default is 1:1. This indicates that, by default, detailed measures will be generated every time this test runs, and also every time the test detects a problem. You can modify this frequency, if you so desire. Also, if you intend to disable the detailed diagnosis capability for this test, you can do so by specifying none against DD frequency. |
Detailed Diagnosis |
To make diagnosis more efficient and accurate, the eG Enterprise embeds an optional detailed diagnostic capability. With this capability, the eG agents can be configured to run detailed, more elaborate tests as and when specific problems are detected. To enable the detailed diagnosis capability of this test for a particular server, choose the On option. To disable the capability, click on the Off option. The option to selectively enable/disable the detailed diagnosis capability will be available only if the following conditions are fulfilled:
|
Measurement | Description | Measurement Unit | Interpretation |
---|---|---|---|
LUNs with ALUA conflicts |
Indicates the number of LUNs that were mapped to both FCP and iSCSI initiator groups with the ALUA setting being enabled in both/atleast one of these initiator groups. |
Number |
A non-zero value is indicative of the existence of LUN conflicts. These conflicts can either be resolved by unmapping one or more mappings from the conflicting LUN or by disabling the ALUA setting on FCP or iSCSI or both the initiator groups whichever is applicable. The detailed diagnosis capability of this measure if enabled, lists out the path of the LUNs with this ALUA setting conflict. |