NetApp iSCSI Connections Test
The iSCSI protocol is a licensed service on the storage system that enables you to transfer block data to hosts using the SCSI protocol over TCP/IP. The iSCSI protocol standard is defined by RFC 3720. In an iSCSI network, storage systems are targets that have storage target devices, which are referred to as LUNs (logical units). A host with an iSCSI host bus adapter (HBA), or running iSCSI initiator software, uses the iSCSI protocol to access LUNs on a storage system. The iSCSI protocol is implemented over the storage system’s standard gigabit Ethernet interfaces using a software driver. The connection between the initiator and target uses a standard TCP/IP network. No special network configuration is needed to support iSCSI traffic. The network can be a dedicated TCP/IP network, or it can be your regular public network. The storage system listens for iSCSI connections on TCP port 3260.
This test monitors the iSCSI connections to the storage system, reports the load imposed by these connections on the storage device, and reveals the nature of these connections - i.e., the number of new connections, the number of connections used for data transfer, the number of connections used for discovery, and more.
Target of the test : A NetApp Unified Storage
Agent deploying the test : An external/remote agent
Outputs of the test : One set of results for the NetApp storage system being monitored.
Parameters | Description |
---|---|
Test Period |
How often should the test be executed. |
Host |
The host for which the test is to be configured. |
Port |
Specify the port at which the specified host listens in the Port text box. By default, this is NULL. |
User |
Here, specify the name of the user who possesses the following privileges: login-http-admin,api-aggr-check-spare-low,api-aggr-list-info,api-aggr-mediascrub-list-info,api-aggr-scrub-list-info,api-cifs-status,api-clone-list-status,api-disk-list-info,api-fcp-adapter-list-info,api-fcp-adapter-stats-list-info,api-fcp-service-status,api-file-get-file-info,api-file-read-file,api-iscsi-connection-list-info,api-iscsi-initiator-list-info,api-iscsi-service-status,api-iscsi-session-list-info,api-iscsi-stats-list-info,api-lun-config-check-alua-conflicts-info,api-lun-config-check-cfmode-info,api-lun-config-check-info,api-lun-config-check-single-image-info,api-lun-list-info,api-nfs-status,api-perf-object-get-instances-iter*,api-perf-object-instance-list-info,api-quota-report-iter*,api-snapshot-list-info,api-vfiler-list-info,api-volume-list-info-iter*. If such a user does not pre-exist, then, you can create a special user for this purpose using the steps detailed in Creating a New User with the Privileges Required for Monitoring the NetApp Unified Storage. |
Password |
Specify the password that corresponds to the above-mentioned User. |
Confirm Password |
Confirm the Password by retyping it here. |
Authentication Mechanism |
In order to collect metrics from the NetApp Unified Storage system, the eG agent connects to the ONTAP management APIs over HTTP or HTTPS. By default, this connection is authenticated using the LOGIN_PASSWORD authentication mechanism. This is why, LOGIN_PASSWORD is displayed as the default authentication mechanism. |
Use SSL |
Set the Use SSL flag to Yes, if SSL (Secured Socket Layer) is to be used to connect to the NetApp Unified Storage System, and No if it is not. |
API Port |
By default, in most environments, NetApp Unified Storage system listens on port 80 (if not SSL-enabled) or on port 443 (if SSL-enabled) only. This implies that while monitoring the NetApp Unified Storage system, the eG agent, by default, connects to port 80 or 443, depending upon the SSL-enabled status of the NetApp Unified Storage system - i.e., if the NetApp Unified Storage system is not SSL-enabled (i.e., if the Use SSL flag above is set to No), then the eG agent connects to the NetApp Unified Storage system using port 80 by default, and if the NetApp Unified Storage system is SSL-enabled (i.e., if the Use SSL flag is set to Yes), then the agent-NetApp Unified Storage system communication occurs via port 443 by default. Accordingly, the API Port parameter is set to default by default. In some environments however, the default ports 80 or 443 might not apply. In such a case, against the API Port parameter, you can specify the exact port at which the NetApp Unified Storage system in your environment listens, so that the eG agent communicates with that port for collecting metrics from the NetApp Unified Storage system. |
vFilerName |
A vFiler is a virtual storage system you create using MultiStore, which enables you to partition the storage and network resources of a single storage system so that it appears as multiple storage systems on the network. If the NetApp Unified Storage system is partitioned to accommodate a set of vFilers, specify the name of the vFiler that you wish to monitor in the vFilerName text box. In some environments, the NetApp Unified Storage system may not be partitioned at all. In such a case, the NetApp Unified Storage system is monitored as a single vFiler and hence the default value of none is displayed in this text box. |
Timeout |
Specify the duration (in seconds) beyond which the test will timeout if no response is received from the device. The default is 120 seconds. |
Measurement | Description | Measurement Unit | Interpretation |
---|---|---|---|
Number of initiators logged in |
Indicates the number of initiators that were currently logged in. |
Number |
This measure reports the number of hosts with the initiator software that are currently accessing the LUNs on the storage device. This measure is a good indicator of the current workload of the device. |
Number of existing connections |
Indicates the number of connections that were already established. |
Number |
This measure is a good indicator of the current workload of the device. |
Number of new connections |
Indicates the number of connections that are not yet part of a session. |
Number |
|
Number of discovery sessions |
Indicates the number of iSCSI sessions that are used to obtain information about iSCSI targets. |
Number |
|