Equipment PSU Control - Intersight Test

A Cisco equipment chassis managed by Cisco Intersight can be provided with one or more hot-swappable power supplies. Each power supply is fitted with a control unit which maintain the inputs and output power voltage. As issues in the power supply units can adversely impact the performance of the blade servers in a chassis, administrators need to promptly detect power-related issues and rectify them before any irrepairable damage is done.

This test aids in the timely detection of issue with power supply control unit by collection of key metrics like status of power supply control, status of input and output power etc.

Target of the test : Cisco Intersight

Agent deploying the test : A remote agent

Outputs of the test : One set of results for each PSU control managed by Cisco Intersight

Configurable parameters for the test

Parameter

Description

Test period

How often should the test be executed.

Host

The IP address of the Host

Port

The port number through which Cisco Intersight communicates.

API Key ID

Specify the ID for API key which is used to authenticate the eg Agent connectivity to Cisco Intersight.

API Key Filepath

Specify the filepath from where eG Agent can read the API Key.

URL

Specify the URL for Cisco Intersight. the default is intersight.com.

Proxy Host

Specify the IP address of the proxy host server.

Proxy Port

Specify the port number of the proxy host server.

Proxy User Name

The user name for the proxy server authentication.

Proxy Password

The password for the proxy server authentication.

Confirm Password

Specify the passowrd again.

Detailed Diagnoses

To make diagnosis more efficient and accurate, the eG Enterprise embeds an optional detailed diagnostic capability. With this capability, the eG agents can be configured to run detailed, more elaborate tests as and when specific problems are detected. To enable the detailed diagnosis capability of this test for a particular server, choose the On option. To disable the capability, click on the Off option.

The option to selectively enable/disable the detailed diagnosis capability will be available only if the following conditions are fulfilled:

  • The eG manager license should allow the detailed diagnosis capability
  • Both the normal and abnormal frequencies configured for the detailed diagnosis measures should not be 0.
Measurements made by the test

Measurement

Description

Measurement Unit

Interpretation

Overall Status

Indicates the current status of PSU control in the equipment chassis.

 

The Status reported by this measure and their corresponding numeric equivalents are described in the table below:

State Numeric Value
Unknown 0
Operable 1
Inoperable 2
Degraded 3
Powered-off 4
Power-problem 5
Removed 6
Voltage-problem 7
Thermal-problem 8
Performance-problem 9
Accessibility-problem 10
Identity-unestablishable 11
Bios-post-timeout 12
Disabled 13
Fabric-conn-problem 51
Fabric-unsupported-conn 52
Config 81
Equipment-problem 82
Decommissioning 83
Chassis-limit-exceeded 84
Not-supported 100
Discovery 101
Discovery-failed 102
Identify 103
Post-failure 104
Upgrade-problem 105
Peer-comm-problem 106
Auto-upgrade 107

Note:

By default, this measure reports the above-mentioned Status while indicating the operating status of each PSU control being managed. However, in the graph of this measure, states will be represented using their corresponding numeric equivalents only.

Input Power State

Indicates the input power state of PSU control in equipment chassis.

 

The State reported by this measure and their corresponding numeric equivalents are described in the table below:

State Numeric Value
Down 0
Ok 1

Note:

By default, this measure reports the above-mentioned States while indicating the presence of each PSU control being managed. However, in the graph of this measure, states will be represented using their corresponding numeric equivalents only.

Output Power State

Indicates the output power state of PSU control in equipment chassis.

 

The State reported by this measure and their corresponding numeric equivalents are described in the table below:

State Numeric Value
Down 0
Ok 1

Note:

By default, this measure reports the above-mentioned States while indicating the presence of each PSU control being managed. However, in the graph of this measure, states will be represented using their corresponding numeric equivalents only.

Cluster State

Indicate the state of entire cluster of PSU controls in equipment chassis.

 

The State reported by this measure and their corresponding numeric equivalents are described in the table below:

State Numeric Value
Slot-1-master 0
Slot-2-master 1

Note:

By default, this measure reports the above-mentioned States while indicating the presence of each PSU control being managed. However, in the graph of this measure, states will be represented using their corresponding numeric equivalents only.

Redundancy State

Indicates the state of PSU control redundancy created by adding more than one PSU control.

 

The State reported by this measure and their corresponding numeric equivalents are described in the table below:

State Numeric Value
Grid 0

Note:

By default, this measure reports the above-mentioned States while indicating the presence of each PSU control being managed. However, in the graph of this measure, states will be represented using their corresponding numeric equivalents only