VNXe Fan Test
Each Storage Processor has three fan modules above it to dissipate heat away from the storage system. For the system to stay operational, atleast two of the three fans on each SP must be active. If either Storage Processor has two or more fans inactive, the system will save cache contents and shut down automatically. In large production environments, administrators may not desire frequent shut downs of their mission critical systems. Therefore, it is necessary for the administrators to frequently monitor the hardware components of the storage system and ensure that a hardware failure does not contribute to the shut down of the storage system. The VNXe Fans test helps administrators in this regard!
This test reports the current health of each cooling fan in the target storage system. By closely monitoring the health of the cooling fans, fans that are running abnormally and fans that have failed can be identified and replaced at a faster pace!
Target of the test : An EMC VNXe Storage system
Agent deploying the test : A remote agent
Outputs of the test : One set of results for each fan on the target storage system being monitored
Parameters | Description |
---|---|
Test Period |
How often should the test be executed. |
Host |
The host for which the test is to be configured. |
Unisphere CLI Path |
The eG agent uses the command-line utility, UEMCli.exe, which is part of the UniSphere Management Suite, to communicate with and monitor the storage device. To enable the eG agent to invoke the CLI, configure the full path to the CLI in the UniSphere CLI Path text box. |
Username and Password |
Provide the credentials of a user possessing monitor role to access the storage device in the Username and Password text boxes. |
Confirm Password |
Confirm the password by retyping it here. |
VNXe Version |
Select the version of the target EMC VNXe storage system that is to be monitored from this list. By default, 1600 will be chosen from this list. |
Detailed Diagnosis |
To make diagnosis more efficient and accurate, the eG Enterprise embeds an optional detailed diagnostic capability. With this capability, the eG agents can be configured to run detailed, more elaborate tests as and when specific problems are detected. To enable the detailed diagnosis capability of this test for a particular server, choose the On option. To disable the capability, click on the Off option. The option to selectively enable/disable the detailed diagnosis capability will be available only if the following conditions are fulfilled:
|
Measurement | Description | Measurement Unit | Interpretation | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Health state |
Indicates the current health of this cooling fan. |
|
The values reported by this measure and its numeric equivalents are mentioned in the table below:
Note: By default, this measure reports the Measure Values listed in the table above to indicate the current health of this cooling fan. The graph of this measure however is represented using the numeric equivalents only - 0 to 7. The detailed diagnosis of this measure lists the ID of the fan, the slot, health, serial number and model of the fan. |