HP P2000 Traps Test

This test intercepts the SNMP traps sent out by the HP P2000 storage system and reports the number and details of the SNMP trap messages so sent.

Target of the test : A HP P2000 SAN storage system

Agent deploying the test : A remote agent

Outputs of the test : One set of results for each of the traps configured for the storage system being monitored

Configurable parameters for the test
Parameter Description

Test period

How often should the test be executed .

Host

The host for which the test is to be configured.

SourceAddress

Specify a comma-separated list of IP addresses or address patterns of the hosts from which traps are considered in this test. For example, 10.0.0.1,192.168.10.*. A leading '*' signifies any number of leading characters, while a trailing '*' signifies any number of trailing characters.

OIDValue

Provide a comma-separated list of OID and value pairs returned by the traps. The values are to be expressed in the form, DisplayName:OID-OIDValue. For example, assume that the following OIDs are to be considered by this test: .1.3.6.1.4.1.9156.1.1.2 and .1.3.6.1.4.1.9156.1.1.3. The values of these OIDs are as given hereunder: 

OID

Value

.1.3.6.1.4.1.9156.1.1.2

Host_system

.1.3.6.1.4.1.9156.1.1.3

NETWORK

In this case the OIDValue parameter can be configured as Trap1:.1.3.6.1.4.1.9156.1.1.2-Host_system,Trap2:.1.3.6.1.4.1.9156.1.1.3-Network, where Trap1and Trap2 are the display names that appear as descriptors of this test in the monitor interface.

An * can be used in the OID/value patterns to denote any number of leading or trailing characters (as the case may be). For example, to monitor all the OIDs that return values which begin with the letter 'F', set this parameter to Failed:*-F*.

Typically, if a valid value is specified for an OID in the OID-value pair configured, then the test considers the configured OID for monitoring only when the actual value of the OID matches with its configured value. For instance, in the example above, if the value of OID .1.3.6.1.4.1.9156.1.1.2 is found to be Host and not Host_system, then the test ignores OID .1.3.6.1.4.1.9156.1.1.2 while monitoring. In some cases however, an OID might not be associated with a separate value – instead, the OID itself might represent a value. While configuring such OIDs for monitoring, your OIDValue specification should be: DisplayName:OID-any. For instance, to ensure that the test monitors the OID .1.3.6.1.4.1.9156.1.1.5, which in itself, say represents a failure condition, then your specification would be:

Trap5: .1.3.6.1.4.1.9156.1.1.5-any.

ShowOID

Specifying True against ShowOID will ensure that the detailed diagnosis of this test shows the OID strings along with their corresponding values. If you enter False, then the values alone will appear in the detailed diagnosis page, and not the OIDs.

ServicePort

The Management Controller of the HP P2000 storage system provides access for monitoring and management via the HTTP and HTTPS protocols for XML API request/response semantics. To enable the eG agent to access the management controller, invoke the XML API commands, and collect the required metrics, you need to specify the service port on the controller that listens for HTTP/HTTPS requests for XML API semantics. By default, this is port 80.

TrapOIDs

By default, this parameter is set to all, indicating that the eG agent considers all the traps received from the specified Sourceaddresses. To make sure that the agent considers only specific traps received from the SourceAddress, then provide a comma-separated list of OIDs in the TrapOIDs text box. A series of OID patterns can also be specified here, so that the test considers only those OIDs that match the specified pattern(s). For instance, *94.2*,*.1.3.6.1.4.25*, where * indicates leading and/or trailing spaces.

DD Frequency

Refers to the frequency with which detailed diagnosis measures are to be generated for this test. The default is 1:1. This indicates that, by default, detailed measures will be generated every time this test runs, and also every time the test detects a problem. You can modify this frequency, if you so desire. Also, if you intend to disable the detailed diagnosis capability for this test, you can do so by specifying none against DD frequency. 

Detailed Diagnosis

To make diagnosis more efficient and accurate, the eG Enterprise embeds an optional detailed diagnostic capability. With this capability, the eG agents can be configured to run detailed, more elaborate tests as and when specific problems are detected. To enable the detailed diagnosis capability of this test for a particular server, choose the On option. To disable the capability, click on the Off option.

The option to selectively enable/disable the detailed diagnosis capability will be available only if the following conditions are fulfilled:

  • The eG manager license should allow the detailed diagnosis capability
  • Both the normal and abnormal frequencies configured for the detailed diagnosis measures should not be 0.
Measurements made by the test
Measurement description Measurement Unit Interpretation

Number of events

Indicates the number of trap messages of this type that is currently being sent from this storage system.

Number