Hitachi Switch Modules LED Test

Each switch module of the target Hitachi Compute Blade contains a set of LEDs using which the administrator can easily identify the health of the switch module. If the LEDs are found to be faulty or is damaged, then problematic switch modules may not be identified instantly which may sometimes lead to malfunctioning of the target Hitachi Compute Blade and its corresponding business services. In order to avoid such issues, it is necessary for the administrators to replace the faulty LEDs at the earliest. This is where the Hitachi Switch Modules LED test helps!

Using this test, administrators can determine the current status of each LED on the switch module and color of each LED. This way, administrators may be alerted to failure of the LEDs and help them replace the LEDs immediately.

Target of the test : Hitachi Compute Blade

Agent deploying the test : An external agent

Outputs of the test : One set of results for each Switch Module:LED pair on the Hitachi Compute Blade being monitored.

The figure below depicts the test configuration page of this test. Click on the parameters in the figure below to know what they are and how to configure them.

Measurements made by the test
Measurement Description Measurement Unit Interpretation
LED status:

Indicates the current status of this LED.

 

The values that this measure can report and the numeric values they indicate have been listed in the table below:

Measure Value Numeric Value

Turn Off

1

Turn On

2

Unknown

3

Blink

4

Blink Fast

5

Blink Slow

6

Note:

By default, this measure can report the Measure Values mentioned above while indicating the current status of each LED in the switch module. However, the graph of this measure is indicated using the numeric equivalents.

LED color:

Indicates the color emitted by this LED.

 

The values that this measure can report and the numeric values they indicate have been listed in the table below:

Color Numeric Value

Blue

1

Green

2

Red

3

Amber

4

Unknown

0

Note:

By default, this measure can report the Colors mentioned above while indicating the color of this LED. However, the graph of this measure is indicated using the numeric equivalents.