Infoblox High Availability Test
High Availability (HA) in Infoblox typically refers to a setup where two appliances (or virtual instances) are paired to act as an active-passive cluster, with failover capabilities and state synchronization.
By continuously monitoring the target appliance, this test reveals if the Infoblox appliance is in high availability pair and reports if the switchover had happened recently.
Target of the test : An Infoblox appliance
Agent deploying the test : An external agent
Outputs of the test : One set of results for the Infoblox appliance that is to be monitored.
| Parameter | Description |
|---|---|
|
Test Period |
How often should the test be executed. |
|
Host |
The IP address of the Infoblox appliance for which this test is to be configured. |
|
Timeout |
Specify the duration (in seconds) within which the SNMP query executed by this test should time out in this text box. The default is 60 seconds. |
|
Is Debug Enabled |
By default, this flag is set to No. If you wish to obtain troubleshooting logs for this test, then, set this flag to Yes. The troubleshooting log with the naming convention <Component Name_Internal name of the test>.log will be created in the <eG_INSTALL_DIR>\agant\logs folder once the test starts reporting metrics. |
| Measurement | Description | Measurement Unit | Interpretation | ||||||
|---|---|---|---|---|---|---|---|---|---|
|
Is HA enabled? |
Indicates whether/not the HA status in enabled. |
|
The values reported by this measure and their numeric equivalents are available in the table below:
Note: This measure reports the Measure Values listed in the table above to indicate if high availability is enabled or not. However, in the graph, this measure is indicated using the Numeric Values listed in the above table. |
||||||
|
Is active node? |
Indicates whether/not the target appliance is in active node. |
|
The values reported by this measure and their numeric equivalents are available in the table below:
Note: This measure reports the Measure Values listed in the table above to indicate if the target appliance is in active node or not. However, in the graph, this measure is indicated using the Numeric Values listed in the above table. |
||||||
|
Has switchover occurred? |
Indicates whether/not switchover had occurred. |
|
The values reported by this measure and their numeric equivalents are available in the table below:
Note: This measure reports the Measure Values listed in the table above to indicate if switchover had occurred or not. However, in the graph, this measure is indicated using the Numeric Values listed in the above table. |