EMC Unity Power Supplies Test
This test auto-discovers the power supply units on the target storage system and for each power supply unit, reports the current health. Using this test, administrators may be alerted to power supply units that failed/degraded and replace those power supply units well before users complain that the target storage system is inaccessible.
Target of the test : An EMC Unity Storage System
Agent deploying the test : A remote agent
Outputs of the test : One set of results for each power supply unit on the target storage system being monitored.
Parameter | Description |
---|---|
Test Period |
How often should the test be executed. |
Host |
The IP address of the storage system for which this test is to be configured. |
UniSphere CLI Path |
The eG agent uses the command-line utility, UEMCli.exe, which is part of the UniSphere Management Suite, to communicate with and monitor the storage device. To enable the eG agent to invoke the CLI, configure the full path to the CLI here. |
Username and Password |
Provide the credentials of a user possessing 'monitor' role to access the storage system in the Username and Password text boxes. |
Confirm Password |
Confirm the Password by retyping it in the Confirm Password text box. |
Timeout |
Specify the duration (in seconds) beyond which this test should time out in the Timeout text box. The default is 300 seconds. |
Detailed Diagnosis |
To make diagnosis more efficient and accurate, the eG Enterprise embeds an optional detailed diagnostic capability. With this capability, the eG agents can be configured to run detailed, more elaborate tests as and when specific problems are detected. To enable the detailed diagnosis capability of this test for a particular server, choose the On option. To disable the capability, click on the Off option. The option to selectively enable/disable the detailed diagnosis capability will be available only if the following conditions are fulfilled:
|
Measurement | Description | Measurement Unit | Interpretation | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Health state |
Indicates the current health of this power supply unit. |
|
The values reported by this measure and its numeric equivalents are mentioned in the table below:
Note: By default, this measure reports the Measure Values listed in the table above to indicate the current health of this power supply unit. The graph of this measure however is represented using the numeric equivalents only - 0 to 7. The detailed diagnosis of this measure lists the ID, Storage processor, slot, health, manufacturer model and serial number of the power supply unit. |